AC-DC 12W - 12V 1A Test Report
SMPS 12V1A TDLOGY sample
|
Top side |
Bottom side |
|
|
|
Test Result
1. Input Characteristics
1.1. Maximum rated input AC current
Input 180Vac 47-63Hz full load
|
VIN(AC) |
180VAC |
198VAC |
|
IIN_RMS |
0.155A |
0.147A |
1.2. No Load Input Power Dissipation
Standard: Single range input 230Vac and the output is no load, the input power loss must be less than 0.1W
Result: PASS.
|
VIN(AC) |
230VAC |
Requirements |
|
Pout = 0W |
60mW |
<0.1W |
1.3. Average Efficiency
Standard: Single range 230Vac
Test Condition: on PCB
|
Vin(Vac) |
Fline(Hz) |
Iout(A) |
Vout(V) |
Pout(W) |
Pin(W) |
Eff (%) |
Eff_AVG(%) |
|
230 |
50 |
1 |
12.24 |
12.23 |
14.5 |
84.34 |
83.59 |
|
0.75 |
12.24 |
9.17 |
10.89 |
84.21 |
|||
|
0.5 |
12.198 |
6.093 |
7.26 |
83.93 |
|||
|
0.25 |
12.15 |
2.907 |
3.55 |
81.89 |
|||
|
0.1 |
12.1 |
1.199 |
1.548 |
77.45 |
77.45 |
||
|
No Load |
12.05 |
|
0.06 |
|
|
2. Output Characteristics
2.1. Ripple & Noise
Standard: under the input voltage 198Vac~264Vac, output on PCB, Vripple <150mVp-p
Waveforms (198Vac & 264Vac):
|
Test Condition: 198Vac/50Hz Input, 12V/1A Output |
Test Condition: 198Vac/50Hz Input, 12V/0A Output |
|
VOUT_RIPPLE_PP = 51.2mVp-p
|
VOUT_RIPPLE_PP = 31.2mVp-p
|
|
Test Condition: 264Vac/50Hz Input, 12V/1A Output |
Test Condition: 264Vac/50Hz Input, 12V/0A Output |
|
VOUT_RIPPLE_PP = 50.4 mVp-p
|
VOUT_RIPPLE_PP = 32.8 mVp-p |
2.2. Output Voltage / Current Characteristics
Standard: Output voltage regulation ±5%
2.3. Start Time & Rise Time
Waveforms:
|
Test Condition: 198Vac/50Hz Input, 12V/1A Output |
Test Condition: 198Vac/50Hz Input, 12V/1A Output |
|
|
|
|
TSTARTUP = 1.8s |
TRISE = 16ms |
2.4. Hold-up Time
Waveforms:
|
Test Condition: 198Vac/50Hz Input, 12V/1A Output |
Test Condition: 230Vac/50Hz Input, 12V/1A Output |
|
|
|
|
Tholdup = 32.6ms |
Tholdup = 48ms |
2.5. Output Overshoot
Waveforms:
|
Test Condition: 198Vac/50Hz Input, 12V/0A Output |
Test Condition: 198Vac/50Hz Input, 12V/1A Output |
|
|
|
|
Vovershoot = 0mV |
Vovershoot = 0mV |
2.6. Load Transient Test
Waveforms:
|
Test Condition: 198Vac/50Hz Input, 10% to 90%,10ms, 50% |
Test Condition: 198Vac/50Hz Input,10% to 90%, 500ms, 50% |
|
|
|
|
VH=12.7V, VL=12V |
VH=12.7V, VL=11.8V |
3. Protection Requirements
3.1. Over Current Protection
|
Input Voltage |
OCP(A) |
|
198Vac/50Hz |
1.2 |
|
230Vac/50Hz |
1.21 |
|
264Vac/50Hz |
1.21 |
3.2. Short Circuit Protection
Waveforms:
|
Test Condition: 198Vac/50Hz Input, 1A to short |
Test Condition: 198Vac/50Hz Input, short to 1A |
|
|
|
|
CH1-VOUT, CH2-VCE |
CH1-VOUT, CH2-VCE |
4. EMI
|
Test Condition: 230Vac/50Hz Input, 12V/1A Output |
|
|
|
Conduction EMI - Line |
|
Test Condition: 230Vac/50Hz Input, 12V/1A Output |
|
|
|
Radiated EMI |