Skip to main content

AC-DC 10W 5V2A Test Report

SMPS 5V2A TDLOGY sample

Top side

Bottom side

 

Test Result

1. Input Characteristics
1.1. Maximum rated input AC current
Input 180Vac 47-63Hz full load

VIN(AC)

180VAC

198VAC

IIN_RMS

0.155A

0.147A

 

1.2. No Load Input Power Dissipation
Standard:
Single range input 230Vac and the output is no load, the input power loss must be less than 0.1W
Result: PASS.

VIN(AC)

230VAC

Requirements

Pout = 0W

68mW

<0.1W

 

1.3. Average Efficiency
Standard:
Single range 230Vac
Test Condition: on PCB

Vin(Vac)

Fline(Hz)

Iout(A)

Vout(V)

Pout(W)

Pin(W)

Eff (%)

Eff_AVG(%)

230

50

2

5.15

10.3

13.26

77.68

77.72

1.5

5.145

7.72

9.91

77.90

1

5.125

5.12

6.56

78.05

0.5

5.105

2.55

3.3

77.27

0.2

5.06

1.012

1.372

73.76

73.76

No Load

5.05

 

0.068

 

 

 

 



2. Output Characteristics
2.1. Ripple & Noise
Standard:
under the input voltage 180Vac~264Vac, output on PCB, Vripple <80mVp-p

 

 

 

Waveforms (198Vac & 264Vac):

Test Condition: 180Vac/50Hz Input, 5V/2A Output

Test Condition: 180Vac/50Hz Input, 5V/0A Output

 

 

VOUT_RIPPLE_PP = 48mVp-p

 

 

 

VOUT_RIPPLE_PP = 40.8mVp-p

 

Test Condition: 264Vac/50Hz Input, 5V/2A Output

Test Condition: 264Vac/50Hz Input, 5V/0A Output

 

VOUT_RIPPLE_PP = 47.2 mVp-p

 

 

 

VOUT_RIPPLE_PP = 32.8 mVp-p

 

 

2.2. Output Voltage / Current Characteristics
Standard:
Output voltage regulation ±5%

 

 

 

 

 

 

 

 

2.3. Start Time & Rise Time
Waveforms:

Test Condition: 180Vac/50Hz Input, 5V/2A Output

Test Condition: 180Vac/50Hz Input, 5V/2A Output

 

 

 

TSTARTUP = 1.8s

TRISE = 9.6ms

 

2.4. Hold-up Time
Waveforms:

Test Condition: 180Vac/50Hz Input, 5V/2A Output

Test Condition: 264Vac/50Hz Input, 5V/2A Output

 

 

 

 

Tholdup = 28ms

Tholdup = 70.6ms

 

2.5. Output Overshoot
Waveforms:

Test Condition: 180Vac/50Hz Input, 5V/0A Output

Test Condition: 180Vac/50Hz Input, 5V/2A Output

 

 

 

Vovershoot = 0mV

Vovershoot = 0mV

 

2.6. Load Transient Test
Waveforms:

Test Condition: 180Vac/50Hz Input, 10% to 90%,10ms, 50%

Test Condition: 180Vac/50Hz Input,10% to 90%, 500ms, 50%

 

 

 

 

VH=5.46V, VL=4.96V

VH=5.46V, VL=4.8V

 

 

 

3. Protection Requirements

3.1. Over Current Protection

Input Voltage

OCP(A)

180Vac/50Hz

2.31

230Vac/50Hz

2.31

264Vac/50Hz

2.31

 

3.2. Short Circuit Protection

Waveforms:

Test Condition: 264Vac/50Hz Input, 2A to short

Test Condition: 264Vac/50Hz Input, short to 2A

CH1-VOUT, CH2-VCE

CH1-VOUT, CH2-VCE

 

 

 

 

 

4. EMI

Test Condition: 230Vac/50Hz Input, 5V/2A Output

Conduction EMI - Line

 

Test Condition: 230Vac/50Hz Input, 5V/2A Output